HAUSE fully premixed high-efficiency low nitrogen condensing gas boiler
+
  • HAUSE fully premixed high-efficiency low nitrogen condensing gas boiler

Product Details

Product Brief

HAUSE fully premixed high-efficiency low nitrogen condensing gas boiler, equipped with cast aluminum condensing heat exchanger and variable frequency premixed combustion system, accurately controls the air-fuel ratio, improves thermal efficiency by early flue gas condensation, reduces nitrogen oxide emissions through low-temperature combustion, and is suitable for small and medium-sized commercial scenarios such as residential areas, office buildings, schools, and government buildings.

 

Key Features

  • Large cast aluminum condenser heat exchanger, high-power fully premixed variable frequency fan+proportional gas valve, precise adjustment of air-fuel ratio
  • Raise the dew point of flue gas, allowing it to enter the condensation stage earlier, resulting in higher thermal efficiency and reduced air demand
  • Reduce flame temperature, decrease nitrogen oxide (NO ₓ) emissions, and be more environmentally friendly
  • Specially customized for small and medium-sized commercial spaces such as residential areas, office buildings, nursing homes, kindergartens, government buildings, etc
     
     

Product Parameters

Output optionsApplicable area (flat)
350 kw3500-4500
700 kw7000-8750
1050 kw10000-13000
1400 kw10000-17500

 

powerunit350 kW700 kW1050 kW1400 kW
Gas category---Natural gas (12T)Natural gas (12T)Natural gas (12T)Natural gas (12T)
Rated heat inputkW35070010501400
Minimum heat inputkW70140200280
Rated heating output 80/60℃kW34067910201358
Rated condensing heat output 50/30℃kW367729.410951458.8
Maximum outlet temperature℃90909090
Exhaust temperature 80/60℃℃<70℃<70℃<70℃<70℃
Smoke exhaust temperature 50/30℃℃<45℃<45℃<45℃<45℃
energy efficiency rating---Level ILevel ILevel ILevel I
Heating temperature regulation range℃20~8020~8020~8020~80
Boiler thermal efficiency%103103103103
Maximum allowable trafficm³/h2040.160.180.2
Minimum inlet water temperature rise℃15151515
Minimum allowable flowm³/h8.617.225.834.4
Maximum inlet water temperature rise℃35353535
Maximum water side pressure lossmH2O0.851.741.691.69
Minimum water side pressure lossmH2O0.450.320.310.32
Minimum/maximum operating pressureMPa0.02/0.10.02/0.10.02/0.10.02/0.1
Gas supply pressure 12TPa2000~70002000~70002000~70002000~7000
Maximum flow rate of gas (12T)m³/h36.873.5108.2147.2
Minimum flow rate of gas (12T)m³/h7.3614.720.328.2
Maximum gas consumption for heatingm³/h36.873.5105210
Hot water supply capacity (△ t=20℃)m³/h14.829.544.390.3
CO emissionsppm<40<40<40<40
NOX emissionsmg/Nm³<30<30<30<30
NOX level---5555
Protection level---IP40IP40IP40IP40
Gas flange interface---DN32DN50DN50DN65
Outlet flange interface---DN60DN100DN100DN100
Return flange interface---DN60DN100DN100DN100
Flue interfacemmφ200φ250φ250φ300
Condensation drainage interface---DN25DN25DN25DN25
Power Supply Nature---220~/ 50~220~/ 50~380~/ 50~380~/ 50~
electric powerW450300030002200
Net quantitykg360605790995
gross weightkg4106708601100
widthmm680102010201170
lengthmm15461871.22185.22893
heightmm1265165516551670
(HTS series) Heightmm15771966.51966.52000
Heating aream²3500~45007000~875010000~1350010000~17500

 

 

Installation Diagram


Belongs to category:

File Download

Factory Strength

1
2

Certifications

ISO Three‑system Certificates

ISO Three‑system Certificates

Environmental Management System Certification Certificate

Environmental Management System Certification Certificate

Occupational Health and Safety Management System Certification

Occupational Health and Safety Management System Certification

Product Inquiry

*Warm reminder: Please be sure to fill in the information accurately and keep the communication open. We will contact you as soon as possible.

Submit

Related Products

Input information to obtain data

OK
%{tishi_zhanwei}%
HAUSE fully premixed high-efficiency low nitrogen condensing gas boiler
+
  • HAUSE fully premixed high-efficiency low nitrogen condensing gas boiler

HAUSE fully premixed high-efficiency low nitrogen condensing gas boiler


Summary Description:

Specially tailored for small and medium-sized places such as residential areas, office buildings, nursing homes, kindergartens, government buildings, etc

Keywords:

Commercial Boilers