Product Details
Product Brief
R20 is an instant electric water heater (Intertek certified, compliant with UL 499/CSA C22.2 No.64) designed for the North American market. It features a digital panel control, 1/2-inch NPT interface, and is positioned for tank hot water and storage water heater pressurization. Note: The actual photo shows the 11 kW version (240V); The instruction manual version is R20A-90 (9 kW), and both calibers are listed in the table below.
Power range
| Model | Rated Power | Rated Voltage | Recommended wire diameter | Circuit breaker specifications | Source |
| R20A-90 | 9 kW | 240V~ | 8AWG | 40A Bipolar | Instruction Manual |
| R20-11 | 11000W(11 kW) | 240V 60Hz | — (Current 45.8A) | — | Documentation |
Product Parameters
| project | Parameters (instruction manual R20A-90/documentation R20-11) |
| Product Type | Instant electric water heater (single-phase, North American version) |
| Temperature setting range | 30-55 ℃ (digital panel setting, factory preset 40 ℃) |
| Start traffic | 0.476GPM/1.8L/min (instruction manual); The data document also indicates a rated water flow rate of 4.92L/min (R20-11) |
| Safety work pressure | 87 PSI (approximately 0.6 MPa) |
| Waterway interface | 1/2 inch NPT, with inlet and outlet located at the bottom of the fuselage |
| Heating technology | Cast aluminum heating element (documentation) |
| waterproof rating | IPX25 (Document R20-11) |
| Panel material | Tempered glass+ABS, LED temperature display (document R20-11) |
| Product Dimensions | 9.84 × 2.6 × 16.14 inches (250 × 66 × 410mm) |
| weight | 9.04 lbs approximately 4.1kg |
| Applicable scenarios | Sink (sink/kitchen) hot water, storage water heater pressurization (recommended in the manual) |
| Water output reference | Inlet at 10 ℃ and outlet at 42 ℃, approximately 0.9GPM; Inlet water at 20 ℃, approximately 1.5GPM (kitchen faucet); Inlet water at 25 ℃, approximately 2.0GPM (shower) |
| safety protection | Leakage protection (E1), over temperature warning (E2,>65 ℃), inlet and outlet water temperature sensor fault detection (E3/E4), zero crossing detection (E5), communication fault (EC) |
Core Functions & Selling Points
- Instant hot water output, ready to use.
- Digital panel temperature control, with a 1 ℃ step adjustment button.
- Cast aluminum heating element with high thermal efficiency.
- Multiple electrical safety protections, with fault code self diagnosis.
- Compact body (thickness only 66mm), flexible installation.
Key Installation Requirements
- The North American version of 240V power supply requires a bipolar circuit breaker and a permanent connection to the main distribution box (plug sockets are prohibited).
- It must have an independent dedicated circuit and be reliably grounded.
- The use of PVC is prohibited for hot water outlets, and CPVC or high temperature resistant pipes are required.
- Suggest installing anti scaling/descaling devices at the inlet end; Before the first power on, drain the water for 2-3 minutes to release the air.
Belongs to category:
File Download
Factory Strength
Certifications
ISO Three‑system Certificates
Environmental Management System Certification Certificate
Occupational Health and Safety Management System Certification
Product Inquiry
Related Products
R20 series · Gas Water Heater
Summary Description:
Keywords:
Gas Water Heater