Product Details
Product Brief
V11 is a single-phase 220V household instant electric water heater with ABS surface shell, induction touch control+LED display, cast aluminum heating element, and water electricity separation structure, which can be turned on and washed immediately, suitable for household shower scenes.
Power range
| Model | Rated Power | Rated Voltage | Recommended wire diameter | Circuit breaker specifications | rated pressure | Source |
| V11-90 | 9000W(9 kW) | 220V~ 50Hz | 10mm² | ≥50A | 0.6MPa | Instruction Manual |
| V11-120 | 12000W(12 kW) | 220V~ 50Hz | 10mm² | ≥63A | 0.6MPa | Instruction Manual |
| V11-8.5 | 8500W(8.5 kW) | 220V | Copper core wire ≥ 6mm ² | — | — | Documentation |
Product Parameters
| project | Parameters (Instruction Manual V11-120/Data Document V11 Series) |
| Product Type | Instant electric water heater (single-phase) |
| Temperature setting range | 30~55℃ |
| Surface shell material | ABS |
| Control method | Inductive touch control, LED display; The manual version is button controlled |
| Heating technology | Cast aluminum heating element, water electricity separation structure |
| Product Dimensions | 405×247×67mm |
| safety protection | Circuit breaker/grounding/electronic leakage/anti leakage wall quadruple depth anti leakage; Double over temperature protection; Bipolar disconnect temperature controller dry burn protection; Inlet and outlet water temperature sensors, leakage, zero crossing self-test (E1~E5, EC) |
| Activation conditions | Inlet pressure ≥ 0.05MPa; The water flow rate needs to meet the start-up requirements |
Core Functions & Selling Points
- Instant wash, no need to wait (water and electricity separation, ready to use immediately).
- Cast aluminum heating element, with high thermal efficiency and more energy saving.
- Inductive touch control+LED display (V11 series shell version).
- Stepless temperature regulation, automatic constant temperature, reaching the set temperature in a few seconds.
- Four fold anti leakage system (including anti electric wall), multiple fault self check.
Key Installation Requirements
- Single phase 220V power supply, 9 kW version circuit breaker ≥ 50A, 12 kW version ≥ 63A, copper core wire diameter ≥ 6-10mm ².
- It must be reliably grounded with a grounding resistance of less than 4 Ω.
- Circuit breakers with leakage protection must be installed in a waterproof location.
- The hanger is installed on the load-bearing wall (with 4 expansion bolts and a hole depth of 25mm); Hot water pipes over 3 meters require insulation.
Belongs to category:
File Download
Factory Strength
Certifications
ISO Three‑system Certificates
Environmental Management System Certification Certificate
Occupational Health and Safety Management System Certification
Product Inquiry
Related Products
V11 series · Gas Water Heater
Summary Description:
Keywords:
Gas Water Heater