C-series · New Low Nitrogen Gas Wall‑Hung Gas Boiler
+
  • C-series · New Low Nitrogen Gas Wall‑Hung Gas Boiler

Product Details

Product Brief

The BOROA C series new low nitrogen gas wall-hung gas boiler operates with low noise without disturbing daily life. It is equipped with intelligent frequency conversion to adapt to all seasons and continuously and stably outputs constant temperature heating and domestic hot water. The whole machine is low in consumption, low in nitrogen, environmentally friendly, and equipped with a complete safety protection system, providing long-term protection for the comfort of the whole house throughout the four seasons.

 

Key Features

  • 92% high thermal efficiency, energy-saving and environmentally friendly
  • Segmented combustion technology, precise temperature control, bidding farewell to sudden changes in temperature
  • Triple anti freezing protection, ensuring peace of mind even in extremely cold weather
  • 46 decibels low noise operation, quiet and not disturbing daily life
  • Intelligent frequency conversion regulation, energy-saving constant temperature dual online

 

Product Parameters

Output optionsApplicable area (flat)
20 kW70-120
26 kW100-160
32 kW160-200
40 kW250-360

 

C-series New Low Nitrogen Gas Wall‑Hung Gas Boiler
Technical parameters/power20 kW26 kW32 kW40 kW
Gas categorynatural gas
Rated gas pressure (Pa)2000
Rated maximum heat load for heating (kW)20.0 26.0 32.0 40.0 
Rated maximum heat output for heating (kW)18.0 24.0 29.3 36.0 
Rated heat load of domestic hot water (kW)20.0 26.0 32.0 40.0 
Minimum rated heating load (kW)8.0 10.4 12.8 16.0 
Heating rated minimum heat output (kW)7.2 9.6 11.7 14.4 
Minimum rated heat load of domestic hot water (kW)8.0 10.4 12.8 16.0 
Rated minimum heat output of domestic hot water (kW)7.2 9.6 11.7 14.4 
Ignition power (kW)12.0 15.6 19.2 24.0 
Thermal efficiency at rated input power (%)92 92 92 92 
Thermal efficiency at 30% input power (%)90 90 90 90 
Maximum working water pressure of heating system (MPa)0.3 0.3 0.3 0.3 
Maximum heating temperature (℃)80 80 80 80 
Temperature regulation range: Cooling fins (℃)30-8030-8030-8030-80
Temperature regulation range: underfloor heating (℃)30-6030-6030-6030-60
Maximum applicable water pressure for domestic hot water system (MPa)0.8 0.8 0.8 0.8 
Minimum applicable water pressure for domestic hot water system (MPa)0.025 0.025 0.025 0.025 
Minimum flow rate of domestic hot water (kg/min)3 3 3 3 
Nominal hot water production rate (△t=25K) (kg/min)10.3 13.8 16.8 20.6 
Stable water temperature flow rate (kg/min)>6>6>6>6
Maximum electrical power at full load (W)120 120 132 145 
Minimum Load Electric Power (W)100 100 100 100 
Standby power (W)2 2 2 2 
Electrical ProtectionClass IClass IClass IClass I
Protection level of shell (IP)X4DX4DX4DX4D
Expansion tank capacity (L)6.5-86.5-810/1210/12
Original pressure of expansion tank (MPa)0.1 0.1 0.1 0.1 
Power supply properties (V/Hz)220~/50220~/50220~/50220~/50
Reference gas consumption (12T natural gas) (m³/h)0.75-2.150.98-2.791.20-3.431.58-4.28
Reference heating area (m)70-120100-160160-200250-360
Net weight/gross weight (kg)31.5/3632.5/37.537/4238.5/43.5
Rated minimum valve back pressure (Pa)150 150 150 150 
Rated load valve pressure (Pa)1200 1200 1200 1300 
Product dimensions (length x width x height) mm710×420×276710×420×345
Packaging dimensions (length x width x height) mm810×490×340810×490×410

Note: The above parameters are for reference only, please refer to the actual product.

 

Installation Diagram

 


File Download

Factory Strength

1
2

Certifications

ISO Three‑system Certificates

ISO Three‑system Certificates

Environmental Management System Certification Certificate

Environmental Management System Certification Certificate

Occupational Health and Safety Management System Certification

Occupational Health and Safety Management System Certification

Product Inquiry

*Warm reminder: Please be sure to fill in the information accurately and keep the communication open. We will contact you as soon as possible.

Submit

Related Products

Input information to obtain data

OK
%{tishi_zhanwei}%
C-series · New Low Nitrogen Gas Wall‑Hung Gas Boiler
+
  • C-series · New Low Nitrogen Gas Wall‑Hung Gas Boiler

C-series · New Low Nitrogen Gas Wall‑Hung Gas Boiler


Summary Description:

Variable frequency segmented wall-hung (gas) boiler

Keywords:

Atmospheric Gas Wall‑Hung Boiler