Product Details
Product Brief
The EM series wall-hung (gas) boiler is equipped with segmented combustion ± 1 ℃ constant temperature technology, ensuring stable water output. Thermal efficiency exceeds 92%, low nitrogen environmental protection, and operates at 45 decibels with low noise. Equipped with more than 20 safety protections, supporting remote control of smart heating cloud mobile phones, providing comfortable and worry free heating and hot water.
Key Features
- Interval segmented combustion+± 1 ℃ constant temperature control, stable water temperature at multiple points, no sudden cold or hot changes
- Heat exchange optimization with a heat efficiency of over 92%, low nitrogen emissions reaching national level 4, high efficiency, energy saving and more environmentally friendly
- 20 layers of safety protection, low-noise fan operation as low as 45 decibels, quiet and reassuring at home
- Intelligent Warm Cloud Mobile Remote Interconnection, Real time View of Energy Consumption and Fault Repair, Intelligent IoT Control
Product Parameters
| Output options | Applicable Area (Square Meters) |
| 26 kw | 100-160 |
| 32 kw | 160-260 |
| 40 kw | 250-360 |
| EM series interval segmented gas wall-hung gas boiler | |||
| Technical parameters/power | 26 kW | 32 kW | 40 kW |
| Gas category | Natural gas (12T) | ||
| Rated gas pressure (Pa) | 2000 | ||
| Rated maximum heat load for heating (kW) | 26.0 | 32.0 | 40.0 |
| Rated maximum heat output for heating (kW) | 24.0 | 29.3 | 36.0 |
| Rated heat load of domestic hot water (kW) | 26.0 | 32.0 | 40.0 |
| Minimum rated heating load (kW) | 9.1 | 11.2 | 14.0 |
| Heating rated minimum heat output (kW) | 7.7 | 9.5 | 12.3 |
| Minimum rated heat load of domestic hot water (kW) | 3.8 | 4.5 | 5.2 |
| Rated minimum heat output of domestic hot water (kW) | 3.2 | 3.9 | 4.4 |
| Ignition power (kW) | 15.6 | 19.2 | 24.0 |
| Thermal efficiency at rated input power (%) | 92 | 92 | 92 |
| Thermal efficiency at 30% input power (%) | 90 | 90 | 90 |
| Maximum working water pressure of heating system (MPa) | 0.3 | 0.3 | 0.3 |
| Maximum heating temperature (℃) | 80 | 80 | 80 |
| Temperature regulation range: Cooling fins (℃) | 30-80 | 30-80 | 30-80 |
| Temperature regulation range: underfloor heating (℃) | 25-60 | 25-60 | 30-60 |
| Maximum applicable water pressure for domestic hot water system (MPa) | 0.8 | 0.8 | 0.8 |
| Minimum applicable water pressure for domestic hot water system (MPa) | 0.025 | 0.025 | 0.025 |
| Minimum flow rate of domestic hot water (kg/min) | 3 | 3 | 3 |
| Nominal heat generation rate (△ t=25K) (kg/min) | 13.8 | 16.8 | 20.6 |
| Maximum electrical power at full load (W) | 120 | 132 | 145 |
| Minimum Load Electric Power (W) | 100 | 100 | 100 |
| Standby power (W) | 2 | 2 | 2 |
| Electrical Protection | Class I | Class I | Class I |
| Protection level of shell (IP) | X4D | X4D | X4D |
| Expansion tank capacity (L) | 6.5-8 | 6.5-8 | 6.5-8 |
| Original pressure of expansion tank (MPa) | 0.1 | 0.1 | 0.1 |
| Power supply properties (V/Hz) | 220~/50 | 220~/50 | 220~/50 |
| Reference gas consumption (12T natural gas) (m³/h) | 0.42.2.79 | 0.48/3.43 | 0.58-4.28 |
| Reference heating area (m²) | 100-160 | 160-260 | 250-360 |
| Net weight/gross weight (kg) | 37/42 | 37/42 | 38.5/43.5 |
| Product dimensions (length x width x height) mm | 724×420×343 | ||
| Packaging dimensions (length x width x height) mm | 860×490×420 | ||
| Rated minimum valve back pressure (Pa) | 150 | 150 | 150 |
| Rated load valve rear pressure (Pa) | 1300 | 1300 | 1300 |
Note: The above parameters are for reference only, please refer to the actual product.
Installation Diagram


Belongs to category:
File Download
-
File size: 17.5MB
Factory Strength
Certifications
ISO Three‑system Certificates
Environmental Management System Certification Certificate
Occupational Health and Safety Management System Certification
Product Inquiry
Related Products
EM Series · Interval Segmented Gas Heating Water Heater
Summary Description:
Keywords:
Atmospheric Gas Wall‑Hung Boiler