Product Details
Product Brief
The BOROA X1 series conventional segmented gas wall-hung gas boiler has balanced and stable segmented combustion water temperature, low-noise operation, quiet and worry free operation, rapid and delicate temperature control of water output, stable output of constant temperature heating and domestic hot water, low energy consumption, green environmental protection, equipped with more than 20 safety protection systems, effectively guarding the comfort of the whole house throughout the four seasons.
Key Features
- Segmented combustion with uniform heating and stable water temperature, bidding farewell to sudden changes in temperature
- 45 decibels ultra quiet, running quietly without disturbing sleep
- Thermal efficiency of 92%, low nitrogen emissions, energy-saving and environmentally friendly
- ± 1 ℃ precise temperature control, fast hot water output, comfortable bathing
- 20+security measures, multiple protection for safer use
Product Parameters
| Output options | Applicable area (flat) |
| 26 kW | 100-160 |
| 32 kW | 160-260 |
| X1 series conventional segmented gas wall-hung gas boiler | ||
| Technical parameters/power | 24 kW | 32 kW |
| Gas category | natural gas | |
| Rated gas pressure (Pa) | 2000 | |
| Rated maximum heat load for heating (kW) | 26.0 | 32.0 |
| Rated maximum heat output for heating (kW) | 24.0 | 29.3 |
| Rated heat load of domestic hot water (kW) | 26.0 | 32.0 |
| Minimum rated heating load (kW) | 9.1 | 11.2 |
| Heating rated minimum heat output (kW) | 7.7 | 9.5 |
| Minimum rated heat load of domestic hot water (kW) | 3.8 | 4.5 |
| Rated minimum heat output of domestic hot water (kW) | 3.2 | 3.9 |
| Ignition power (kW) | 15.6 | 19.2 |
| Thermal efficiency at rated input power (%) | 92 | 92 |
| Thermal efficiency at 30% input power (%) | 90 | 90 |
| Maximum working water pressure of heating system (MPa) | 0.3 | 0.3 |
| Maximum heating temperature (℃) | 80 | 80 |
| Temperature regulation range: Cooling fins (℃) | 30-80 | 30-80 |
| Temperature regulation range: underfloor heating (℃) | 30-60 | 30-60 |
| Maximum applicable water pressure for domestic hot water system (MPa) | 0.8 | 0.8 |
| Minimum applicable water pressure for domestic hot water system (MPa) | 0.025 | 0.025 |
| Minimum flow rate of domestic hot water (kg/min) | 3 | 3 |
| Nominal hot water production rate (△ t=25K) (kg/min) | 13.8 | 16.8 |
| Maximum electrical power at full load (W) | 120 | 132 |
| Minimum Load Electric Power (W) | 100 | 100 |
| Standby power (W) | 2 | 2 |
| Electrical Protection | Class I | Class I |
| Protection level of shell (IP) | X4D | X4D |
| Expansion tank capacity (L) | 6.5-8 | 10/12 |
| Original pressure of expansion tank (MPa) | 0.1 | 0.1 |
| Power supply properties (V/Hz) | 220~/50 | 220~/50 |
| Reference gas consumption (12T natural gas) (m³/h) | 0.98-2.79 | 1.20-3.43 |
| Rated minimum valve back pressure (Pa) | 150 | 170 |
| Rated load valve pressure (Pa) | 1200 | 1300 |
| Net weight/gross weight (kg) | 27.5/29.5 | 32/36 |
| Product dimensions (length x width x height) mm | 690×417×243 | 690×417×325 |
| Packaging dimensions (length x width x height) mm | 805×495×310 | 810×490×410 |
Note: The above parameters are for reference only, please refer to the actual product.
Installation Diagram

Belongs to category:
File Download
-
File size: 10.7MB
Factory Strength
Certifications
ISO Three‑system Certificates
Environmental Management System Certification Certificate
Occupational Health and Safety Management System Certification
Product Inquiry
Related Products
X1 Series · Conventional Segmented Gas Heating Water Heater
Summary Description:
Keywords:
Atmospheric Gas Wall‑Hung Boiler